PIERRE Wiki B2B Portal
PIERRE Display – Monaco 12.3"
Pro Wave

PIERRE Display – Monaco 12.3"

Set up the PIERRE Monaco 12.3" smart control panel: its features, power and wiring, adding it in the Smart PIERRE app, the display settings, relays and troubleshooting.

9 min read Beginner Updated 2026-11-29
Relays Wave Humidity/Temperature/Brightness Display PoE Modbus

Description

The PIERRE Smart Control Panel Monaco 12.3" is a wide-format wall-mounted control panel with a 12.3-inch touchscreen (1920 × 720 px). It runs Android 11 on a quad-core Cortex-A55 processor with 2 GB RAM and 16 GB storage, and connects over Ethernet with PoE or over Wi-Fi. It has five relay outputs, eight inputs, built-in sensors and works as a PIERRE Wave (Zigbee 3.0, 2.4 GHz) gateway.

Touchscreen

  • 12.3-inch touchscreen, 1920 × 720 px.
  • Lighting, climate control and other Smart PIERRE functions on a wide-format screen.

Intercom Function

The Monaco is the indoor part of the PIERRE intercom system. Calls from the outdoor intercom unit ring on the display, where the resident sees the visitor live on the intercom's camera and talks through the built-in speaker and microphone. The display itself sends no video.

PIERRE Wave Gateway

The display works as a gateway for PIERRE Wave products over Zigbee 3.0.

Local Mode

The display runs as a local server, so the system keeps working when the internet connection is unavailable. Local operation supports device control, automations, scenes and wireless communication. Some cloud-dependent functions still require an active internet connection.

Integrated Relays

  • Five relay outputs. Relays 1–4 switch the common L onto L1–L4, 250 W per circuit; relay 5 is a separate changeover contact (NO, COM, NC).
  • For switching compatible electrical loads, such as underfloor heating valves and other heating and cooling devices.

RS-485 / Modbus

  • Two RS-485 buses for Modbus devices; each Modbus device is assigned to bus 1 or bus 2.

Inputs

  • Eight inputs for presence, door and window, tamper, smoke, flood and rain sensors.

Integrated Sensors

  • Temperature sensor
  • Humidity sensor
  • Brightness sensor
  • Presence sensor (radar), shown in the app as a motion sensor.

Network Connectivity

  • 10/100 Mbit/s Ethernet, RJ45, with PoE (IEEE 802.3af/at).
  • 2.4 GHz Wi-Fi (802.11 b/g/n).
  • PIERRE Wave (Zigbee).
  • Modbus (2 × RS-485).

Technical Notes

Plan the power supply before installation. The Monaco runs on 12 V DC, 2 A, or on PoE (IEEE 802.3af/at), and draws about 5 W. It does not need a neutral, a ground or a separate mains circuit.

Plan for two 86 wall boxes, not one. The mounting bracket fixes onto 2 × 86 boxes. Place the boxes and the cable entries during the electrical design.

Bring every cable you may need to the wall box at the start. This includes the network cable, the relay conductors for all five outputs, the inputs and both RS-485 buses, even if they are not used at first. Adding conductors later means opening the wall. Keep relay loads within 250 W per circuit.

Mount the bracket with the hooks facing up and outward, or the display will not clip on.

The built-in temperature, humidity and brightness sensors measure at the display position. On a wall warmed by the sun, or above a radiator, the readings will not represent the room. In those spots, use a separate room sensor.

Indoor, dry rooms only. The display is rated IP20 and is not waterproof. It works from 0 to +40 °C at 5–90% RH, non-condensing.

No direct connection to a controller is needed. The display joins the system over the network. Switch off the power before connecting or changing any wiring.

How to Add the Monaco 12.3" Display in the Smart PIERRE App

Add the Monaco 12.3" display to the building in the Smart PIERRE app: connect it to the network first, then scan the QR code shown on the display and set the display user's name, role and permissions.
Connect the display to the internet
1

Connect the display to the internet

  • Ethernet: plug the network cable into the display.
  • Wi-Fi: on the display, pull down the status bar, tap Wi-Fi, choose your network and enter the password if one is needed.

Important: set the connection you use (Wi-Fi or Ethernet) as the priority connection on the display, and turn off the one you don't use.

Open Displays in the Smart PIERRE app
2

Open Displays in the Smart PIERRE app

Open Menu and, under Settings, tap Displays.

Path: Menu → Settings → Displays.

Scan the QR code
3

Scan the QR code

Scan the QR code shown on the display with your smartphone.

Invite the new display
4

Invite the new display

Scanning the code invites a new display user. Tap Done to confirm.

Fill in the required fields
5

Fill in the required fields

  • Display Name: a name you will recognise.
  • Manage Self: turn this on to let users change their own profile data (name, image) on the display.
  • Role Access: pick the role that sets which I/Os in the building the display can reach.
Set the permissions
6

Set the permissions

The options are: Use I/Os, Manage I/Os, Manage Dashboards, Manage Users, Manage Roles, Manage Bridges, Location Restriction and All Time / Limited Time. You only see the permissions that you have yourself.

PIERRE Display Monaco 12.3" Settings

Open the display in the Smart PIERRE app (Menu → Settings → Displays) and adjust its settings tab by tab. The changes are saved with Submit, Save or Done.
Open Displays
1

Open Displays

Open Menu and, under Settings, tap Displays.

Choose the Monaco display
2

Choose the Monaco display

Tap the Monaco display in the list.

Display settings
3

Display settings

The display settings have these sections:

  • Name: edit the name of the display.
  • Info: versions and updates (see the next step).
  • Activity: every action in the system, with who did it and when.
  • Access: the roles the display can use.
  • Personalization: the interface, features and permissions of the display.
  • Sensors: the integrated sensors.
  • PIERRE Wave: the wireless devices of the integrated gateway (shown when PIERRE Wave is enabled).
  • Relays: the outputs connected to the relays.
  • Modbus: the Modbus devices connected to the display.
Info
4

Info

  • Target Build: the version the display updates to (available to authorised users only).
  • Display Type: the model of the display.
  • Application Version: the installed application version.
  • Launcher Version: the installed launcher version.
  • New Version Available!: tap Update to install the latest display firmware.
  • Reboot: restart the display.
Activity
5

Activity

Shows every action in the system: which device was used, by whom and when.

Access
6

Access

Set time-based access (All Time or Limited Time) and add a role with Add new Role Access. The list shows the current access permissions.

Add new Role Access
7

Add new Role Access

Tap the field next to Add new Role Access to add a new role.

Edit Access
8

Edit Access

Turn each permission on or off with its slider:

  • Use I/Os: open and close doors, switch lights on and off and use other I/Os in this place.
  • Manage I/Os: create automations for I/Os and edit I/Os.
  • Manage Dashboards: reorder, create and remove dashboards in this place.
  • Manage Users: add or remove other users' access to this place.
  • Manage Roles: add, remove and edit roles for this place.
  • Location Restriction: allow I/O use only within a set radius around the building.
  • All Time: access every day, all day.
  • Limited Time: access only on the days and hours you set.

Tap Save to confirm, or Delete to remove the access.

Personalization
9

Personalization

Turn these features on or off:

  • Bottom Tabs: show the bottom tabs in the application.
  • Dashboard Picker: show the dashboard picker.
  • Building Picker: show the building picker.
  • Manage Self: let the user edit their own profile (name, image).
  • PIERRE Wave: enable or disable the PIERRE Wave gateway on the display.
  • Control Network: let the display manage its own network settings (Wi-Fi, Ethernet IP settings).
  • Layout Change: let the display change its own dashboard layout.

Tap Submit to confirm.

Sensors
10

Sensors

Tap any sensor to edit it.

Edit the temperature sensor
11

Edit the temperature sensor

  • Name: the name of the sensor.
  • Photo: choose the source of the photo.
  • Temperature Offset: when enabled, set it with +/−.
  • Temperature Format: choose Celsius or Fahrenheit.

Tap Submit, then Done to confirm.

Edit the humidity sensor
12

Edit the humidity sensor

  • Name: the name of the sensor.
  • Photo: choose the source of the photo.
  • Humidity Offset: when enabled, set it with +/−.

Tap Done, then Submit to confirm.

Relays
13

Relays

Shows the outputs connected to the five relays. Tap an output to edit it, or tap Add Output to add one. Tap Done to confirm.

Add Output: choose the type
14

Add Output: choose the type

Choose the type from the list:

  • Light
  • Fan
  • Electrical Outlet
  • Passive Heating
  • Valve
  • Irrigation
Output settings
15

Output settings

  • Name: the name of the output.
  • Roles: the roles that can use the output.
  • Dashboard: the dashboard where the I/O is shown.
  • Output: the relay the consumer is connected to (Relay 1 to Relay 5).
  • Photo: the photo of the output.
  • Slide to confirm: ask for a slide before the output switches.
  • Identifier: the identifier from the electrical plan.
  • Hide Activity: hide the I/O's actions from the Activity tab.
  • Timeout: how long the I/O stays on after an automation or another I/O switches it on.

Cables

PositionWiresCross-sectionTypeCommentCategory
From PIERRE Display to network switch (PoE)1-Cat 5e U/UTPNetwork and PoE powerRecommended
From PIERRE Display to 12 V DC power supply20.75 mm²H05V-K12 V+, GND (12 V DC, 2 A)Required without PoE
From PIERRE Display to RS-485 device20.5 mm²LIYCYA, BOptional

Troubleshooting

Q
The display shows as offline in the app. What should I check?
A

Check the power supply (PoE switch or injector, or the 12 V DC supply) and the network connection (Ethernet cable or Wi-Fi signal). Restart the display. If it is still offline, contact PIERRE support with the building name and the display's name.

Q
Wireless (PIERRE Wave) devices stopped responding. What should I do?
A

Check that the Monaco is powered and online, since it acts as their gateway. Devices far from the display may need a closer position or a mains-powered Wave device in between to extend the mesh.

Q
What happens if the internet goes down?
A

The system keeps working locally without internet access, but remote access (such as controlling devices from a phone while away) is not possible.

Q
Do displays need to be connected to a controller?
A

No. Displays connect to the system through the network, wired or wireless, and do not need a direct connection to a controller.

Q
Does the Monaco need a mains (L/N) connection?
A

No. The Monaco runs on PoE (IEEE 802.3af/at) over the RJ45 port, or on a separate 12 V DC, 2 A power supply.

Q
Can the Monaco display work as a thermostat?
A

Yes. The Monaco has a built-in temperature sensor and five relay outputs, so it can control heating and cooling devices like a thermostat.

Was this page helpful?