Magnetic sensor embedded for windows
| SKU | PP-SNS-MSEW |
|---|---|
| Product line | PIERRE Pro |
| Category | Sensors / Contact sensors |
| Manufacturer | Shenzhen E-5continents.Co |
| Manufacturer SKU | 5c-35 |
| GTIN / EAN | 8606034720499 |
| HS code | 9031808000 |
Overview
The PIERRE Pro Magnetic sensor embedded for windows is recessed into the frame and the opening leaf so that nothing is visible when the window is shut — the alternative to a surface contact where appearance matters or where a surface unit would be knocked.
It is a magnetic reed switch with a normally-closed contact, so the circuit opens when the window opens and a broken cable reads as an alarm rather than as silence.
The detection gap is 20-35 mm, which allows for a little movement in the frame without false alarms. It runs from 12 V DC at up to 0.5 A and wires back to a PIERRE controller input or an alarm panel zone. The housing is ABS in white with concealed screw fixings, operating from -20 °C to +80 °C.
Key features
- Flush-mounted reed contact, invisible when closed
- Normally-closed (NC) contact
- Detection gap 20-35 mm
- 12 V DC, 0.5 A
- For wooden and similar window frames
- Operating temperature -20 to +80 °C
Technical specifications
| Electrical | |
|---|---|
| Power Supply | DC 12V |
| Current | 0.5 A |
| Output Power | NC contact type |
| Physical | |
| Panel Material | ABS plastic |
| Product Color | White |
| Environmental | |
| Operating Temperature (°C) | -20 - +80 |
| Operating Temperature | -4°F ~ +176 °F |
| Safety | |
| Safety Features | Tamper Protection, Door status detection |
| Sensors | |
| Detection Technology | Magnetic reed switch |
Pin layout
| Pin | Label | Type | Position |
|---|---|---|---|
| 1 | COM | power_12V_input | top |
| 2 | Sig | sensor_signal | top |
Physical & packaging
| Dimensions (L × W × H) | 11 × 11 × 33 mm |
|---|---|
| Weight | 7 g |
| Box dimensions (L × W × H) | 11 × 11 × 33 mm |
| Box weight | 7 g |
User manual
1. Product Description
The PIERRE Pro Magnetic sensor embedded for windows is a flush-mounted reed contact that reports whether a window is open or closed. Normally-closed, 12 V DC, wired back to a PIERRE controller input.
The PIERRE wired contact sensor reports whether a door or window is open or closed. It has two parts — a sensor unit and a magnet — and detects the state from the magnetic field between them.
Installation
- The sensor is fitted into the door or window frame and the magnet on the opening part, so both are concealed when the opening is closed.
- The sensor is wired back to a controller input; there is no battery to replace.
- It is configured in the PIERRE Partner application, and then appears in the Smart PIERRE application.
Wired or Wireless
The wired sensor keeps a continuous connection to the controller and never needs a battery, which makes it the better choice where the frame is accessible during the first fix. Where cabling is not possible, the wireless version provides the same function.
Use in Automations
- Reduce or switch off heating and cooling while a window is open.
- Switch on lighting when a door is opened.
- Send an alert when an opening changes state while the property should be empty.
- Trigger an alarm or external lighting as part of a security function.
Technical Notes
- Recessed sensors have to be planned before the frame is fitted. Adding one afterwards means working on a finished frame.
- Keep the magnet gap within specification. On a door that settles over time the gap grows and the sensor starts reporting open.
- Check the sensor's rest state before configuring; a normally-closed sensor reports the opposite of a normally-open one.
- Test every sensor physically at handover, opening and closing the actual door or window.
2. What you need
Wired. Needs a PIERRE PRO or LITE Controller with a free input, plus the Magnetic sensor embedded for windows. The sensor takes 12 V from the controller.
3. Wiring
Wiring PIERRE Contact sensor — electric scheme
| Run | Wires | Cross-section | Cable type | Conductors |
|---|---|---|---|---|
| From Contact sensor to PIERRE Controller | 2 | 0.2 mm² (24 AWG) | Cat 5e U/UTP | +12 V, INPUT |
4. FAQ
Q1: The sensor does not react in the app. What should I check first?
Check that the sensor has been added to the configuration in the PIERRE Partner application.
Q2: The sensor was just added and shows no state. Why?
A newly added sensor needs a state change before it reports. Open and close the door or window once.
Q3: How do I check that the sensor is wired correctly?
It must be connected to 12 V and a PIERRE input as shown in the wiring diagram. To find out whether the fault is in the sensor or in the cable, briefly bridge 12 V to the PIERRE input the sensor uses. If the dot turns green in the app, the fault is the sensor or a broken wire.
Q4: When should input and output be on the same controller?
If one input influences an output, both should be added to the same controller. A motion sensor triggering a lamp, for example, performs best when both sit on the same controller.
Q5: When should contact sensors be installed?
PIERRE Pro contact sensors are installed during construction, because they need wiring in the frame or wall. PIERRE Wave contact sensors are wireless and can be added later.
Q6: Where should the contact sensor be placed?
Sensor and magnet must be aligned when the door or window is closed. On windows, placing the sensor at the top lets it detect a tilted window as open.
Q7: How should the sensors be wired?
Each sensor is wired individually back to the PIERRE cabinet in a star pattern. INPUT 12–24 V takes 12 V DC from the controller, GND takes ground from the controller, switch terminal K1 (IN) is bridged to INPUT 12–24 V, and switch terminal K2 (OUT) goes to the input on the controller.