Relay Board 8ch
| SKU | PP-R8 |
|---|---|
| Product line | PIERRE Pro |
| Category | Relays |
| Manufacturer | JLCPCB |
| Manufacturer SKU | PP-R8 |
| GTIN / EAN | 8606034720130 |
| HS code | 8536419000 |
Overview
The PIERRE Pro Relay Board 8ch allows efficient switching of multiple high-power devices such as lights, motors, and appliances. Each relay channel supports a load capacity of up to 2.5A, with clear labels for inputs and outputs to simplify installation.
The board features reverse polarity, over-voltage, and short circuit protection to ensure safety. It operates with a 12V DC input and is designed to fit standard DIN rail mounts, enabling easy integration into control systems. Built with durable PCB materials, the board ensures reliable performance in various environments.
Key features
8 relay channels, 12V DC input, 20V - 240V AC output, 2.5A max load per channel, over-voltage and short circuit protection, mounting on DIN rail
Technical specifications
| Electrical | |
|---|---|
| Input Voltage | 12V DC V |
| Number of Inputs | 8.0 |
| Number of Outputs | 8.0 |
| Current | 0.01 A |
| Physical | |
| Product Color | White |
| Features | |
| LED Indicators | Yes |
| Environmental | |
| Operating Temperature (°C) | 0°C - +50°C |
| Operating Temperature | +32°F - +122°F |
| Operating Humidity | 10% - 95% RH (non-condensing) % RH |
| Altitude | <3000m |
| Safety | |
| Safety Features | Overload, Over Voltage, Short Circuit, Reverse polarity |
Electrical & I/O
| Operating voltage | 230 V |
|---|---|
| Power consumption | 4 W |
| Max. current | 10 A |
| Recommended circuit breaker | 16 A |
| Connection | L+N+PE |
| Requires neutral | Yes |
| Requires ground | Yes |
| DIN rail | 6 module(s) |
Pin layout
| Pin | Label | Type | Position |
|---|---|---|---|
| 1 | COM1 | relay_com | top |
| 2 | NO1 | relay_no | top |
| 3 | COM2 | relay_com | top |
| 4 | NO2 | relay_no | top |
| 5 | COM3 | relay_com | top |
| 6 | NO3 | relay_no | top |
| 7 | COM4 | relay_com | top |
| 8 | NO4 | relay_no | top |
| 9 | COM5 | relay_com | top |
| 10 | NO5 | relay_no | top |
| 11 | COM6 | relay_com | top |
| 12 | NO6 | relay_no | top |
| 13 | COM7 | relay_com | top |
| 14 | NO7 | relay_no | top |
| 15 | COM8 | relay_com | top |
| 16 | NO8 | relay_no | top |
| 17 | IN1 | coil_a1 | bottom |
| 18 | IN2 | coil_a1 | bottom |
| 19 | IN3 | coil_a1 | bottom |
| 20 | IN4 | coil_a1 | bottom |
| 21 | GND | power_gnd_in | bottom |
| 22 | IN5 | coil_a1 | bottom |
| 23 | IN6 | coil_a1 | bottom |
| 24 | IN7 | coil_a1 | bottom |
| 25 | IN8 | coil_a1 | bottom |
| 26 | GND | power_gnd_in | bottom |
Physical & packaging
| Dimensions (L × W × H) | 105 × 58 × 86 mm |
|---|---|
| Weight | 140 g |
| Box dimensions (L × W × H) | 109 × 64 × 90 mm |
| Box weight | 180 g |
User manual
1. Product Description
- Housing
- Relay Outputs
- Input Terminals
- Input Ground (GND)
2. What you need
Wired. Needs a PIERRE PRO or LITE Controller with a free output, plus the Relay Board 8ch.
3. Product Size
- W: 105 mm
- D: 58 mm
- H: 86 mm
4. Wiring
- Connect +12V to the relay module and the main controller.
- Connect GND to the relay module and the main controller (common ground).
- Connect Live (L) to the COM terminal of each relay output.
- Connect the NO (Normally Open) terminal to the load (e.g. light, motor).
- When the relay is activated, power flows from COM to NO to energize the load.
| Run | Wires | Cross-section | Cable type | Conductors |
|---|---|---|---|---|
| From PIERRE Controller to Relay board | 2 | 0.75 mm² | H07V-K | GND, OUTPUT |
5. Video
PIERRE Academy - Relay Board Setup and Light Installation. https://www.youtube.com/watch?v=n9zJBuLs_iM
PIERRE Academy - Controller Setup. https://www.youtube.com/watch?v=oScvanSTIzg
6. FAQ
Q1: What happens if one relay on the relay board fails?
Move the load to a free relay channel and reassign the controller output in the PIERRE Partner app, or replace the board.