Presence Sensor 360 (Ceiling Mount)
| SKU | PP-SNS-PRESENCE-C |
|---|---|
| Product line | PIERRE Pro |
| Category | Sensors / Motion & Presence Sensors |
| Manufacturer | Gasim |
| Manufacturer SKU | GSA040D |
| GTIN / EAN | 8606034720444 |
| HS code | 9031808000 |
Overview
The PIERRE Pro Presence Sensor 360 operates on a 12-24V DC input and features a dry contact output for flexible integration with various control systems. Using radar-based detection technology at a working frequency of 5.8GHz, the sensor precisely identifies presence through minor motions such as breathing or hand movements, making it ideal for occupancy-based automation. Its versatile design includes adjustable detection areas to suit different room sizes and layouts, along with configurable hold times ranging from 5 seconds to 30 minutes.
This presence sensor incorporates an integrated daylight sensing feature with customizable lux levels or the option to disable it, allowing for energy-efficient lighting management. Designed for ceiling mounting, the sensor covers installation heights between 2m to 8m and maintains reliable performance in diverse lighting conditions. With a plane detection angle of 360°, it is suitable for various applications, including offices, conference rooms, and large commercial spaces.
Key features
5.8GHz radar detection, 12-24V DC input, minor movement detection, dry contact output, 360° detection angle, adjustable detection area, ceiling mount, daylight sensing, configurable hold times.
Technical specifications
| Electrical | |
|---|---|
| Power Supply | DC 12V/24V |
| Frequency | 5.8GHz ±75 MHz, ISM band |
| Output Power | Dry contact NO/NC |
| Physical | |
| Product Color | White |
| Recommended Installation Height | 3 m |
| Environmental | |
| Operating Temperature (°C) | -25 - +50 |
| Operating Temperature | -13°F - +122°F |
| Operating Humidity | Non condensing 85 % RH |
| IP Rating | IP20 |
| Safety | |
| Safety Features | Over voltage protection, Short circuit protection, Anti-flammable housing, Electrostatic protection, Surge protection |
| Sensors | |
| Detection Angle | 360° |
| Detection Technology | Radar-based motion/breathing |
| Adjustable Features | Detection area / hold time / lux levels |
| Detection Area | 100% |
| Daylight Sensor | 5 lux / 25 lux / 50 lux / Disable |
Pin layout
| Pin | Label | Type | Position |
|---|---|---|---|
| 1 | 12V+ | power_12V_input | top |
| 2 | GND | power_gnd_in | top |
| 3 | COM | power_12V_input | top |
| 4 | NO | sensor_signal | top |
Physical & packaging
| Dimensions (L × W × H) | 105 × 23 × 105 mm |
|---|---|
| Weight | 84 g |
| Box dimensions (L × W × H) | 111 × 25 × 114 mm |
| Box weight | 102 g |
User manual
- 1. Dimensions
- 2. What you need
- 3. Structure
- 4. Installation
- 5. Wiring
- 6. Detection Pattern
- 7. Functions
- 8. Dip Switch Settings
- 9. Initialization
- 10. Factory Settings
- 11. Installation Notes and Precautions
- 12. FAQ
1. Dimensions
- 23 mm
- 85 mm
- ∅ 105 mm
- 66 mm
- 65 mm
- ∅ 4.20 mm
- 15 mm
- ∅ 10.50 mm
2. What you need
Wired. Needs a PIERRE PRO or LITE Controller with a free input, plus the Presence Sensor 360 (Ceiling Mount).
3. Structure
- Daylight Harvesting
- Infrared Light
- Detection Area
- Hold Time
- Daylight Sensor
- Indicator Light
- Pilot Light
- Antenna Module
- P1
- P2
- GND
- 12V DC
4. Installation
- Insert a slotted screwdriver into the designated slot on the housing and gently pry to remove the cover.
Caution: Do not use excessive force. Use only insulated tools and follow local electrical safety regulations.
- Use a flat tool to gently lift the cover from the threading hole.
- When surface-mounted, the thin tab on the side of the housing should be removed to create a cable entry groove.
- Connect the wire to the terminal and configure the corresponding parameters as required.
- Secure the device to the designated mounting surface using a compatible screwdriver.
- Ensure the cover is securely fastened after installation, following the arrow indicator as a guide.
5. Wiring
The sensor has four terminals: P1, P2, GND and 12V.
- 12V and GND take the 12 V DC supply from the controller.
- P1 and P2 are the two terminals of the sensor’s switch contact; wire them as described below.
- Connect the +12 V terminal of the sensor to the +12 V output of the controller.
- Connect the GND terminal of the sensor to the GND terminal of the controller.
- Bridge the IN and +12 V terminals on the sensor to enable the output switching logic.
- Connect the OUT terminal of the sensor to a PIERRE input on the controller (e.g. INPUT 1).
| Run | Wires | Cross-section | Cable type | Conductors |
|---|---|---|---|---|
| From presence sensor to PIERRE Controller | 3 | 0.2 mm² (24 AWG) | Cat 5e U/UTP | +12 V, GND, SIGNAL |
One run, three conductors — 12 V, ground and signal — on a single Cat 5e U/UTP home-run to the controller. Identical to the motion sensor run; only the mounting and the detection behaviour differ.
6. Detection Pattern
- Ceiling mount - 3m
- Breathing detection - 3m radius
- Micro Motion Detection - 4m radius
- Motion Detection - 4m radius
7. Functions
Signal detection: The sensor detects walking, slight movements (such as body shifts, head turns, and other minor actions), and breathing to identify human presence during a non-sleep state.
Movement signal: Large or noticeable movement that activates the sensor
Slight motion signal: When only very small body movements are detected, the indicator flashes once.
Breathing signal: When no slight motion is detected, only the breathing signal is collected. The indicator flashes three times after detecting three valid breathing signals.
When the ambient light is sufficient, the light will not turn on even if motion is detected.
When the ambient light is low, motion is detected and the light turns on automatically.
Movements like the body, head, and other small actions are detected during normal use, the light stays on continuously.
When the sensor fails to detect movement or slight motion, the light will automatically turn off after the set delay time
8. Dip Switch Settings
Detection Area
DIP switches 1 and 2 set the sensitivity, i.e. the size of the detection area.
| Position | 1 | 2 | Detection area |
|---|---|---|---|
| I | ON | ON | 100% |
| II | - | ON | 75% |
| III | ON | - | 50% |
| IV | - | - | 25% |
Hold Time
DIP switches 3, 4 and 5 set how long the output stays active after motion is detected.
Note: To enable presence detection (breathing detection), set the hold time to at least 1 minute, preferably longer. The 5-second setting is intended for motion-sensor testing only.
| Position | 3 | 4 | 5 | Hold time |
|---|---|---|---|---|
| I | ON | ON | ON | 5s |
| II | ON | - | ON | 30s |
| III | ON | ON | - | 1 min |
| IV | ON | - | - | 3 min |
| V | - | ON | ON | 5 min |
| VI | - | - | ON | 10 min |
| VII | - | ON | - | 20 min |
| VIII | - | - | - | 30 min |
Daylight Sensor
This table shows how DIP switches 6, 7 and 8 control the daylight (ambient light) threshold. This setting determines when the sensor is allowed to turn on the light, based on the surrounding brightness level.
Note: When set to "Disable", the sensor will turn on the light whenever it detects movement, regardless of the ambient light level.
| Position | 6 | 7 | 8 | Threshold |
|---|---|---|---|---|
| I | ON | ON | ON | 5 Lux |
| II | - | ON | ON | 30 Lux |
| III | ON | - | ON | 50 Lux |
| IV | - | - | ON | 100 Lux |
| V | ON | ON | - | 150 Lux |
| VI | - | - | - | Disable |
Indicator light
DIP switch 9 controls whether the indicator LED on the sensor is ON or OFF.
HS: The indicator light is on.
LS: The indicator light is off.
Note: The indicator is ON by default. It can be turned OFF using the DIP switch or by pressing the LS button on the remote control.
| 9 | |||
|---|---|---|---|
| I | ON | Indicator on (HS) | |
| II | - | Close |
9. Initialization
When powered on for the first time, the sensor enters a self-test mode. This process lasts 20 seconds, after which the sensor switches to normal operation.
During initialization, external motion signals are not detected and remote control signals are ignored.
10. Factory Settings
- Indicator Light: On
- Detection Area: 100%
- Hold Time: 1 minute
- Daylight Sensor: Disabled
11. Installation Notes and Precautions
- Professional Installation Required:
- The sensor must be installed by a qualified electrician. Always disconnect the power before installation, wiring, or changing the dial (DIP) switch settings.
- Avoid Interference from Dense Materials:
- Keep the sensor away from large areas of metal, glass, or other high-density materials to prevent false triggering.
- Avoid Constant Vibration Sources:
- Do not install the sensor near objects that vibrate continuously (e.g. oscillating fans), as vibrations may be detected as motion and cause false triggers.
- Remote Control Feedback:
- The indicator light will flash three times quickly to confirm successful remote control settings.
- Initialization Limitations:
- During initialization (first 20 seconds after power-on), sensing functions are disabled, and sensor parameters cannot be set via remote control.
- Indicator Light Recommendation:
- It is recommended to turn off the indicator light during normal use to save power or reduce distraction.
- Hold Time Recommendations by Room Type:
- In open offices with many people: 30 seconds
- In private offices or smaller spaces: 1 minute or more (ideally 3 minutes or more)
- The sensor's microwave signal can penetrate walls. If the signal reaches outside the intended detection zone, it may trigger due to movement outside.
- To avoid false alarms:
- Avoid installing near materials that microwaves can easily pass through (glass, plasterboard, wooden walls).
- Choose proper installation locations and detection settings based on the room size:
- Room size ~2m x 2m → Set detection area to 25%
(e.g., washroom, small sitting area) - Room size ~3m x 3m → Set detection area to 50%
(e.g., hallway, medium sitting area) - Room size ~4m x 4m → Set detection area to 75%
(e.g., small office, meeting room, library) - Room size ~5m x 5m or larger → Set detection area to 100%
(e.g., large office, conference room, open library)
Note: Detection area settings should be adjusted according to the actual environment. The above examples are for reference only.
- Hold Time Settings Based on Occupancy:
- For single-person spaces: Set hold time between 1–3 minutes
- For multi-person spaces: Set hold time between 30 seconds to 1 minute
- Avoid setting hold time above 5 minutes, as it may cause small movements to continuously reset the timer and prevent the light from turning off.
12. FAQ
Q1: What do the controller LED colours mean?
Green – online and connected. Red – offline, no network or no internet. Light blue – AP mode, broadcasting its own network for setup. Dark blue – AP mode managed through PIERRE Partner. Purple – searching for an IP address from the router. Orange – downloading a firmware update.
Q2: The sensor does not react in the app. What should I check first?
Check that the sensor has been added to the configuration in the PIERRE Partner application.
Q3: The sensor was just added and shows no state. Why?
A newly added sensor needs a state change before it reports. Trigger it, then let it go idle again.
Q4: How do I check that the sensor is wired correctly?
It must be connected to 12 V, GND and a PIERRE input as shown in the wiring diagram, with the IN terminal bridged to +12 V.
Q5: How do I find out whether the fault is in the sensor or in the cable?
Briefly bridge 12 V to the PIERRE input the sensor uses. If the dot turns green in the app, the controller and the configuration are fine and the fault is the sensor or a broken wire.
Q6: When should input and output be on the same controller?
If one input influences an output, both should be added to the same controller. A motion sensor triggering a lamp, for example, performs best when both sit on the same controller.
Q7: What is the difference between presence and motion sensors?
A motion sensor detects movement and suits high-traffic areas like hallways. A presence sensor detects that someone is in the room even when stationary, which suits offices and living areas.
Q8: How should the sensors be wired?
Each sensor is wired individually back to the PIERRE cabinet in a star pattern. INPUT 12–24 V takes 12 V DC from the controller, GND takes ground from the controller, switch terminal K1 (IN) is bridged to INPUT 12–24 V, and switch terminal K2 (OUT) goes to the input on the controller.