PIERRE Wiki B2B Portal

Search

47 results for “contact has:steps has:video”

Page Solutions / Sensors Pro

Solution - Contact Sensor

A contact sensor reports whether an opening is open or closed — a door, window, gate, garage door or any othe…

matched in title, tags, body

Page PIERRE Partner Application / Inputs

PIERRE Partner - Contact Sensor

The Contact Sensor is used to detect the open or closed state of doors, windows, gates, and other movable eleme…

matched in title, body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Magnet Contact Sensor

The Contact sensor section of the Smart PIERRE app shows whether a door or window is open or closed. Sensors ar…

matched in title, body

Page Solutions / Controllers & Power Pro

Solution - Contactors

Contactor Control Description The PIERRE system can control contactors through a Solid State Relay (SSR) or…

matched in title, body

Page Solutions / Heating & Cooling Pro

Solution - Gas Boiler

… Controller controls a relay whose potential-free contact is connected to the boiler's external heat-demand input. By opening or closing this contact, PIERRE…

matched in tags, body

Page Solutions / Doors, Gates & Access Pro

Solution - Gates Control

… Controller controls a relay whose potential-free contact is connected to the gate operator's dry-contact trigger input . The PIERRE system therefore sends t…

matched in tags, body

Page Solutions / Lighting Pro

Solution - Push Button Control

… Controller Input When the button is pressed, the contact closes and sends the 12 V signal back to the corresponding Controller input. The lighting circuit o…

matched in tags, body

Page Fundamentals / Maintenance & Troubleshooting

Fundamentals - Software/Firmware Update Procedure for PIERRE Devices

…ure which firmware version should be used, please contact PIERRE Technical Support before proceeding. Important Notes Ensure the device remains powered and c…

matched in body

Page PIERRE Partner Application / Outputs

PIERRE Partner - Doors Control

…Hide Activity if required. Enable Use Sensor if a contact sensor is fitted, then add the sensor. Submit and save the configuration. To edit a door, open the …

matched in body

Page PIERRE Partner Application / Outputs

PIERRE Partner - Fan Coil

…nly within a time window, stopping while a window contact is open, or reacting to another sensor. In Auto the unit then runs only while the rule is true and …

matched in body

Page PIERRE Partner Application / Inputs

PIERRE Partner - Leakage Sensor

…as a flood sensor, smoke detector, gas sensor, or contact sensor . For sensors with a normally closed (NC) output, use Change inverted . This reverses the in…

matched in body

Page PIERRE Partner Application / Outputs

PIERRE Partner - Lights

…le. Any wall push button for the circuit is a dry contact wired to a controller input. The controller is online in the PIERRE Partner app and has a free outp…

matched in body

Page PIERRE Partner Application / Outputs

PIERRE Partner - Passive Heating and Cooling

…or heating valve, an electric heater, a heat pump contact, a cooling ceiling valve. Before You Start The device is wired through a relay to a free controller…

matched in body

Page PIERRE Partner Application / Profile

PIERRE Partner - Profile

…issue to technical support. Support and privacy — contact details for support and the privacy policy. Log out . Technical Notes Read the app version from her…

matched in body

Page PIERRE Partner Application / Inputs

PIERRE Partner - Push Button

…sh Button input allows connection of external dry-contact push buttons to a PIERRE controller. Each configured button can trigger one or more actions based o…

matched in body

Page PIERRE Partner Application / Outputs

PIERRE Partner - Siren

… Sensor detects movement. Trigger an alarm when a Contact Sensor is activated. Activate a siren when a Safety Detector enters an alarm state. Generate an aud…

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Alarm

…ample: Motion or presence sensors Door and window contact sensors Smoke sensors Leakage sensors Other compatible sensors and I/Os Multiple conditions can be …

matched in body

Page Smart PIERRE Application / Menu & Settings

Smart PIERRE - Alerts

… https://www.youtube.com/embed/_H1KR95IdQ0 Magnet Contact Sensor Notifications Setup Automating a Smoke Detector, Siren, and Alerts https://www.youtube.com/e…

matched in body

Page Smart PIERRE Application / Automations & Scenarios

Smart PIERRE - Delay Function

…ilation is turned OFF. Select the window magnetic contact as the condition. Set the magnetic contact condition to When Open . The delay condition will be bas…

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Doors Control

…of the door, appropriate feedback, such as a door contact sensor , is required. Without such feedback, the PIERRE system may know the issued control command …

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Fan Coil

… a delay or an existing I/O, for example a window contact that stops the unit while the window is open or a presence sensor that runs it only while the room …

matched in body

Page Smart PIERRE Application / Menu & Settings

Smart PIERRE - Keys

…t leads outside. The open/closed state requires a contact sensor on the door or gate. Without it, only the locked state is real — the rest is what was comman…

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Lights

…r an existing I/O such as a motion sensor, a door contact, a brightness sensor or a wall button. Conditions are joined with Or and And, and Add new Logical B…

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Motion Sensor

…he PIERRE Partner app does not match the sensor's contact type. See the Partner Motion Sensor lesson. Wave motion sensors run on a battery and sleep between …

matched in body

Page Smart PIERRE Application / Access & Permissions

Smart PIERRE - Open Doors/Gates via Smartphone

…eadable before acting. Magnetic Sensor A magnetic contact sensor should be fitted so the system knows whether the door or gate is physically open or closed. …

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Passive Heating and Cooling

…rson remains still for an extended period. Window Contact A Window Contact can be used to temporarily stop or modify heating or cooling demand when an open w…

matched in body

Page Smart PIERRE Application / Accommodation

Smart PIERRE - Reservation

… Dive into reservation specifics, including guest contacts, cleaning history, and access tools like digital QR keys or RFID tokens for secure, hassle-free pr…

matched in body

Page Smart PIERRE Application / Functions & Controls

Smart PIERRE - Safety Detectors

…th compatible 12 VDC detectors that provide a dry contact or relay contact output. Supported Devices Smoke detectors. Heat detectors. Gas detectors. LPG dete…

matched in body

Page Solutions / Sensors Pro

Solution - CO and other Gas Sensors

… manufacturer. Technical Notes A compatible relay contact alarm signal can be connected to the PIERRE Controller input. If the detector is powered directly f…

matched in body

Page Solutions / Lighting Pro

Solution - Dimmable Light Control

… 0–10 V Extender and the Dimmer Slave 0–10 V. Dry contact (potential-free) momentary push buttons for the wall positions. The button must be a simple normall…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Door Bell Buttons

A doorbell button is a dry-contact input on a PIERRE controller. When the contact closes, the controller raises a doorbell event, whic…

matched in body

Page Solutions / Sensors Pro

Solution - Leak Sensor

…nput. Most third-party leak sensors provide a dry contact that closes when water is detected — this is the type that connects directly. Keep the cable run aw…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Modbus Integration

…d to 0–10 V and Relay Control Modbus 0–10 V Relay contact Direction Read and write Command only Command only Feedback in the app Real state of the unit: on /…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - ON/OFF HVAC - Passive Heating Cooling (heating pumps)

… If the equipment requires a potential-free / dry-contact thermostat input , an appropriate potential-free contact must be provided from the PIERRE system. E…

matched in body

Page Solutions / Lighting Pro

Solution - ON/OFF Light control

…s own output. Operating the Lighting From the dry-contact push button positions wired to the controller inputs. From the Smart PIERRE app. From scenarios, wh…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Open/Close Door Locks

…nge the pin in the PIERRE Partner app. Should the contact sensor report the open or the closed state? Mount the sensor so that it closes when the door or gat…

matched in body

Page Solutions / Integrations

Solution - PIERRE Alexa Integration

…Alexa, is [device name] open/closed?” (requires a contact sensor) Smart Plugs “Alexa, turn [device name] on/off.” “Alexa, is [device name] on?” Scenes “Alexa…

matched in body

Page Solutions / Irrigation Pro

Solution - Rain Sensor

… be integrated into the PIERRE system using a dry-contact output or relay-based signal. Any rain sensor that provides a compatible contact output can be conn…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Sirens

… various devices and events, including motion and contact sensors, smoke, gas and CO detectors, water leakage sensors, access control events, automation rule…

matched in body

Page Solutions / Sensors Pro

Solution - Smoke and Fire Sensors

…to the controller I/O terminals via its own relay contact, so the detection signal reaches the system reliably. The sensor is configured in the PIERRE Partne…

matched in body

Page Smart PIERRE Application / User Profile

User Profile Settings

…seful application-related information, including: Contact information Privacy policy Terms and conditions (if available) Application version number This info…

matched in body

Page Smart PIERRE Application / User Profile

PIERRE Application Versions

… may be required when: Reporting software issues. Contacting technical support. Verifying compatibility with system components. Confirming installation of th…

matched in body

Page Smart PIERRE Application / Automations & Scenarios

Smart PIERRE - Light Automation

…the light should follow daylight. Door and window contacts, wall buttons, other I/Os – open or closed, pressed, held or double-pressed, active or not active.…

matched in body

Page Solutions / Blinds & Curtains Pro

Solution - Blinds Control

…en it is released. What is wrong? Check the relay contacts and the protection varistor across the relay coil; a damaged relay or varistor can hold or release…

matched in body

Page Solutions / Other devices Pro

Solution - Electrical Load Control

…oller sends a 12V DC control signal to a relay or contactor, and that relay or contactor switches the power supply or the control circuit of the connected de…

matched in body

Page Solutions / Other devices Pro

Solution - Electrical Outlet

…s • HVAC equipment High-power loads may require a contactor instead of a standard relay. Using an undersized relay may result in: • Overheating • Reduced lif…

matched in body

Page Fundamentals / Basics

Solution - PIERRE Controllers

… controlled through an appropriately rated relay, contactor, or other suitable power switching device. GND Ground/reference potential ( 0 V / − ) connection …

matched in body