PIERRE Wiki B2B Portal

Search

19 results for “contact has:video section:solutions”

Page Solutions / Sensors Pro

Solution - Contact Sensor

A contact sensor reports whether an opening is open or closed — a door, window, gate, garage door or any othe…

matched in title, tags, body

Page Solutions / Controllers & Power Pro

Solution - Contactors

Contactor Control Description The PIERRE system can control contactors through a Solid State Relay (SSR) or…

matched in title, body

Page Solutions / Heating & Cooling Pro

Solution - Gas Boiler

… Controller controls a relay whose potential-free contact is connected to the boiler's external heat-demand input. By opening or closing this contact, PIERRE…

matched in tags, body

Page Solutions / Doors, Gates & Access Pro

Solution - Gates Control

… Controller controls a relay whose potential-free contact is connected to the gate operator's dry-contact trigger input . The PIERRE system therefore sends t…

matched in tags, body

Page Solutions / Lighting Pro

Solution - Push Button Control

… Controller Input When the button is pressed, the contact closes and sends the 12 V signal back to the corresponding Controller input. The lighting circuit o…

matched in tags, body

Page Solutions / Sensors Pro

Solution - CO and other Gas Sensors

… manufacturer. Technical Notes A compatible relay contact alarm signal can be connected to the PIERRE Controller input. If the detector is powered directly f…

matched in body

Page Solutions / Lighting Pro

Solution - Dimmable Light Control

… 0–10 V Extender and the Dimmer Slave 0–10 V. Dry contact (potential-free) momentary push buttons for the wall positions. The button must be a simple normall…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Door Bell Buttons

A doorbell button is a dry-contact input on a PIERRE controller. When the contact closes, the controller raises a doorbell event, whic…

matched in body

Page Solutions / Sensors Pro

Solution - Leak Sensor

…nput. Most third-party leak sensors provide a dry contact that closes when water is detected — this is the type that connects directly. Keep the cable run aw…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Modbus Integration

…d to 0–10 V and Relay Control Modbus 0–10 V Relay contact Direction Read and write Command only Command only Feedback in the app Real state of the unit: on /…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - ON/OFF HVAC - Passive Heating Cooling (heating pumps)

… If the equipment requires a potential-free / dry-contact thermostat input , an appropriate potential-free contact must be provided from the PIERRE system. E…

matched in body

Page Solutions / Lighting Pro

Solution - ON/OFF Light control

…s own output. Operating the Lighting From the dry-contact push button positions wired to the controller inputs. From the Smart PIERRE app. From scenarios, wh…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Open/Close Door Locks

…nge the pin in the PIERRE Partner app. Should the contact sensor report the open or the closed state? Mount the sensor so that it closes when the door or gat…

matched in body

Page Solutions / Irrigation Pro

Solution - Rain Sensor

… be integrated into the PIERRE system using a dry-contact output or relay-based signal. Any rain sensor that provides a compatible contact output can be conn…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Sirens

… various devices and events, including motion and contact sensors, smoke, gas and CO detectors, water leakage sensors, access control events, automation rule…

matched in body

Page Solutions / Sensors Pro

Solution - Smoke and Fire Sensors

…to the controller I/O terminals via its own relay contact, so the detection signal reaches the system reliably. The sensor is configured in the PIERRE Partne…

matched in body

Page Solutions / Blinds & Curtains Pro

Solution - Blinds Control

…en it is released. What is wrong? Check the relay contacts and the protection varistor across the relay coil; a damaged relay or varistor can hold or release…

matched in body

Page Solutions / Other devices Pro

Solution - Electrical Load Control

…oller sends a 12V DC control signal to a relay or contactor, and that relay or contactor switches the power supply or the control circuit of the connected de…

matched in body

Page Solutions / Other devices Pro

Solution - Electrical Outlet

…s • HVAC equipment High-power loads may require a contactor instead of a standard relay. Using an undersized relay may result in: • Overheating • Reduced lif…

matched in body