PIERRE Wiki B2B Portal

Search

36 results for “contact line:wave line:pro type:page section:solutions”

Page Solutions / Sensors Pro

Solution - Contact Sensor

A contact sensor reports whether an opening is open or closed — a door, window, gate, garage door or any othe…

matched in title, tags, body

Page Solutions / Controllers & Power Pro

Solution - Contactors

Contactor Control Description The PIERRE system can control contactors through a Solid State Relay (SSR) or…

matched in title, body

Page Solutions / Doors, Gates & Access Pro

Solution - Elevator Control

…ation, the elevator control unit must provide dry-contact inputs for call and/or button commands. In most elevator systems, this type of interface is already…

matched in tags, body

Page Solutions / Doors, Gates & Access Pro

Solution - Garage Door Control

… Controller controls a relay whose potential-free contact is connected to the garage door motor's external push-button or control input. The relay briefly cl…

matched in tags, body

Page Solutions / Heating & Cooling Pro

Solution - Gas Boiler

… Controller controls a relay whose potential-free contact is connected to the boiler's external heat-demand input. By opening or closing this contact, PIERRE…

matched in tags, body

Page Solutions / Doors, Gates & Access Pro

Solution - Gates Control

… Controller controls a relay whose potential-free contact is connected to the gate operator's dry-contact trigger input . The PIERRE system therefore sends t…

matched in tags, body

Page Solutions / Lighting Pro

Solution - Push Button Control

… Controller Input When the button is pressed, the contact closes and sends the 12 V signal back to the corresponding Controller input. The lighting circuit o…

matched in tags, body

Page Solutions / Heating & Cooling Wave

PIERRE Thermostat T2

…rements. Description PIERRE Wave Thermostat - dry contact 230V AC - Electric schemes full Schemes - 230V AC without controller (T2 controls the valves) Cable…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Alarm System Wiring

…er RFID Reader Electromagnetic Lock Motion Sensor Contact Sensor Siren System Functionality The system can provide: Intrusion detection Door and window monit…

matched in body

Page Solutions / Sensors Pro

Solution - CO and other Gas Sensors

… manufacturer. Technical Notes A compatible relay contact alarm signal can be connected to the PIERRE Controller input. If the detector is powered directly f…

matched in body

Page Solutions / Lighting Pro

Solution - Dimmable Light Control

… 0–10 V Extender and the Dimmer Slave 0–10 V. Dry contact (potential-free) momentary push buttons for the wall positions. The button must be a simple normall…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Door Bell Buttons

A doorbell button is a dry-contact input on a PIERRE controller. When the contact closes, the controller raises a doorbell event, whic…

matched in body

Page Solutions / Doors, Gates & Access Pro Wave

Solution - Gate, Garage Door, Parking Ramp Control

…trial access systems Wired Control A standard dry-contact push button is connected directly to a PIERRE Controller input. Sequence: The user presses the push…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Heat Recovery Unit (Recuperator)

…n the unit, control may be implemented using: dry contact / relay inputs , separate inputs for fixed fan speed levels, a 0–10 V control signal, or an appropr…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Heating and Cooling with 0-10V

…t speed. From automation: a schedule, or a window contact that stops the fan. The regulation runs inside the controller, so it keeps working when the interne…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Hot Tub with Massage Jets

…ical Notes Pumps and heaters are switched through contactors sized for their load; the controller relay drives the contactor coil, not the motor. Wet areas h…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - HVAC with Blower Speed

…ighttime. Stopping the unit when a door or window contact detects that it is open. Automatically selecting the required fan speed based on heating or cooling…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - IP Camera Integration

…assigned to the connection. If CGNAT is detected, contact your Internet Service Provider and request a Public Static IP Address . This is the recommended sol…

matched in body

Page Solutions / Sensors Pro

Solution - Leak Sensor

…nput. Most third-party leak sensors provide a dry contact that closes when water is detected — this is the type that connects directly. Keep the cable run aw…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Modbus Integration

…d to 0–10 V and Relay Control Modbus 0–10 V Relay contact Direction Read and write Command only Command only Feedback in the app Real state of the unit: on /…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - ON/OFF HVAC - Passive Heating Cooling (heating pumps)

… If the equipment requires a potential-free / dry-contact thermostat input , an appropriate potential-free contact must be provided from the PIERRE system. E…

matched in body

Page Solutions / Lighting Pro

Solution - ON/OFF Light control

…s own output. Operating the Lighting From the dry-contact push button positions wired to the controller inputs. From the Smart PIERRE app. From scenarios, wh…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Open/Close Door Locks

…nge the pin in the PIERRE Partner app. Should the contact sensor report the open or the closed state? Mount the sensor so that it closes when the door or gat…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Pools

…ical Notes Pumps and heaters are switched through contactors sized for their load; the controller relay drives the contactor coil, not the motor. Pool areas …

matched in body

Page Solutions / Irrigation Pro

Solution - Rain Sensor

… be integrated into the PIERRE system using a dry-contact output or relay-based signal. Any rain sensor that provides a compatible contact output can be conn…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Sirens

… various devices and events, including motion and contact sensors, smoke, gas and CO detectors, water leakage sensors, access control events, automation rule…

matched in body

Page Solutions / Sensors Pro

Solution - Smoke and Fire Sensors

…to the controller I/O terminals via its own relay contact, so the detection signal reaches the system reliably. The sensor is configured in the PIERRE Partne…

matched in body

Page Solutions / Heating & Cooling Pro

Solutions - Fan Coil control

…ontrolled by PIERRE in two ways: • Potential-free contacts: one contact switches winter/summer mode, another starts and stops the heat pump. • Modbus RTU: co…

matched in body

Page Solutions / Blinds & Curtains Pro

Solution - Blinds Control

…en it is released. What is wrong? Check the relay contacts and the protection varistor across the relay coil; a damaged relay or varistor can hold or release…

matched in body

Page Solutions / Blinds & Curtains Pro

Solution - Curtains Control

… end stops and run capacitor, and check the relay contacts for burnt or welded contacts. The motor does nothing and makes no sound. What should I check? Meas…

matched in body

Page Solutions / Other devices Pro

Solution - Electrical Load Control

…oller sends a 12V DC control signal to a relay or contactor, and that relay or contactor switches the power supply or the control circuit of the connected de…

matched in body

Page Solutions / Other devices Pro

Solution - Electrical Outlet

…s • HVAC equipment High-power loads may require a contactor instead of a standard relay. Using an undersized relay may result in: • Overheating • Reduced lif…

matched in body

Page Solutions / Other devices Pro

Solution - Fan/Motor

…otor above the relay rating is switched through a contactor: the relay drives the coil, the contactor carries the load. Control On and off from the app and f…

matched in body

Page Solutions / Blinds & Curtains Pro

Solution - Pergola Control

…ed output module, an appropriately rated relay or contactor must be used. For position-based control, the actual full travel time of the pergola must be meas…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Sauna

…hing must be implemented through a properly rated contactor and a suitably protected electrical circuit. The maximum operating time of the sauna heater must …

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Water Heater

…he PIERRE system, it is essential to use a relay, contactor, or switching device that is correctly rated for the electrical characteristics of the heater. Fo…

matched in body