PIERRE Wiki B2B Portal

Search

36 results for “devices has:table has:diagram”

Page Solutions / Other devices Pro

Solution - Electrical Load Control

Beyond the predefined solution categories, any electrical device that can be switched with simple ON/OFF logic can be integrated. The PIERRE controlle…

matched in tags, path

Page Solutions / Other devices Pro

Solution - Electrical Outlet

…type allows users to control connected electrical devices through the PIERRE system. Electrical outlets can be controlled manually, included in automations, …

matched in path, body

Page Solutions / Other devices Pro

Solution - Fan/Motor

A fan or motor output is used for room ventilation — exchanging air with the outside, or moving air between rooms. It is wired through a relay and dri…

matched in path

Page Fundamentals / Architecture

Fundamentals - PIERRE Architecture

…anagement. PIERRE Gateway — connects the wireless devices. PIERRE Displays — room control, local server and intercom in one unit. PIERRE Intercoms — access m…

matched in body

Page Fundamentals / Architecture

KNX vs. PIERRE

…assemble to get there. KNX is a bus standard. The devices carry the intelligence, and everything the client actually touches — the mobile app, the wall dashb…

matched in body

Page Fundamentals / Basics

PIERRE Display - Berlin 10"

…gateway, handling communication with the wireless devices: Device pairing. Device control. Mesh network management. Wave device communication. Local Mode The…

matched in body

Page Fundamentals / Basics

PIERRE Display - Helsinki 6”

…gateway, handling communication with the wireless devices: Device pairing. Device control. Mesh network management. Wave device communication. Local Mode The…

matched in body

Page Fundamentals / Basics

PIERRE Display - Rio 4”

…gateway, handling communication with the wireless devices: Device pairing. Device control. Mesh network management. Wave device communication. Local Mode The…

matched in body

Page PIERRE Partner Application / PIERRE Controllers

PIERRE Partner - Controller Commissioning

…is installed in the distribution cabinet, and the devices it controls are wired directly to the controller. Specifications 16 digital inputs and 16 digital o…

matched in body

Page PIERRE Partner Application / Configurable I/O Pro

PIERRE Partner - Modbus

… the PIERRE system enables compatible third-party devices to be integrated and controlled or monitored through the PIERRE system. Modbus is widely used in bu…

matched in body

Page Solutions / Controllers & Power

PIERRE Power Supplies - Models

…ower for controllers, network equipment and other devices in the installation. All models are designed for DIN rail mounting, so they fit directly into the e…

matched in body

Page Solutions / Heating & Cooling Wave

PIERRE Thermostat T2

…n WAVE installations, the distance between Zigbee devices and Gateways, as well as walls and building structures, can affect wireless communication. Where Zi…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Alarm System Wiring

…rm signaling functions using standard low-voltage devices connected directly to the controller. System Components The example system includes: PIERRE Pro Con…

matched in body

Page Solutions / Controllers & Power Pro

Solution - Battery Backup

…em supports battery backup operation for critical devices through compatible 12 VDC power supplies with integrated battery charging functionality. During a m…

matched in body

Page Solutions / Sensors Pro

Solution - CO and other Gas Sensors

…ply, system configuration, operation of connected devices, and the network or internet connection required for the relevant function. Description Electrical …

matched in body

Page Solutions / Controllers & Power Pro

Solution - Contactors

… overcurrent, short-circuit, and other protective devices must be sized according to the connected load. Installation must be carried out according to the PI…

matched in body

Page Solutions / Lighting Pro

Solution - Dimmable Light Control

…ts, valves, actuators and other 0–10 V controlled devices whose control input has a maximum short-circuit current of 1 mA. It carries a low-current control s…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Garage Door Control

…e is a power outage? If the power goes out, smart devices will retain their last state and resume functionality when power is restored. For critical devices,…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Gas Boiler

…e is a power outage? If the power goes out, smart devices will retain their last state and resume functionality when power is restored. For critical devices,…

matched in body

Page Solutions / Doors, Gates & Access Pro Wave

Solution - Gate, Garage Door, Parking Ramp Control

…ler keeps its own logic, travel limits and safety devices. Description Schemes - Wiring Gate control - dry contact Schemes - Wiring Gate Motors with Separate…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Gates Control

…the gate operator, system architecture, connected devices, and required operating time. Technical Notes Before connection, verify the gate operator's externa…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Heat Recovery Unit (Recuperator)

…e is a power outage? If the power goes out, smart devices will retain their last state and resume functionality when power is restored. For critical devices,…

matched in body

Page Solutions / Sensors Pro

Solution - Humidity and Temperature Sensors

…connection has been created, add the sensor under Devices : Select Add New Modbus I/O . Select Humidity and Temperature Sensor as the device type. Name – Ent…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - HVAC with Blower Speed

…e is a power outage? If the power goes out, smart devices will retain their last state and resume functionality when power is restored. For critical devices,…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Modbus Integration

…oller (one TTL to RS485 converter each), up to 15 devices per line. Drivers: ready-made drivers for PIERRE devices and supported brands; Generic Modbus for a…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - ON/OFF HVAC - Passive Heating Cooling (heating pumps)

…e is a power outage? If the power goes out, smart devices will retain their last state and resume functionality when power is restored. For critical devices,…

matched in body

Page Solutions / Lighting Pro

Solution - ON/OFF Light control

…is a power outage? If the power goes out, smart devices will retain their last state and resume functionality when power is restored. For critical devices, b…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Open/Close Door Locks

… a mains power failure. For backup operation, all devices required for access must be powered from the PIERRE UPS power supply , including: the PIERRE Contro…

matched in body

Page Fundamentals / Basics

Solution - PIERRE Controllers

…ors, push buttons, switches, and other controlled devices within a PIERRE installation. The Controller Lite can be used for applications such as lighting, sh…

matched in body

Page Fundamentals / Basics

Solution - PIERRE Smart Intercom

…e SIP-based communication . Communication between devices can operate over the local network without an active internet connection. When internet access is a…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Secure Door Locks (motorized)

…ppens if there is a power outage? Controllers and devices keep their last state and resume when power returns. Locks and gate motors can be backed up by a ba…

matched in body

Page Solutions / Doors, Gates & Access Pro

Solution - Sirens

… Automatic activation can be triggered by various devices and events, including motion and contact sensors, smoke, gas and CO detectors, water leakage sensor…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Valve Control

…ts, valves/actuators, and other 0–10 V controlled devices, provided that the device’s 0–10 V control input has a maximum short-circuit current of 1 mA. In ot…

matched in body

Page Solutions / Heating & Cooling Pro

Solutions - Fan Coil control

…ts, valves/actuators, and other 0–10 V controlled devices, provided that the device’s 0–10 V control input has a maximum short-circuit current of 1 mA. In ot…

matched in body

Page PIERRE Partner Application / Inputs

PIERRE Partner - Push Button

The Push Button input allows connection of external dry-contact push buttons to a PIERRE controller. Each configured button can trigger one or more ac…

matched in body

Page Solutions / Heating & Cooling Pro

Solution - Water Heater

Water heaters can be integrated into the PIERRE system using a relay output, enabling automated and remote control of the device. This allows users to…

matched in body