Solution - Pools
Pro

Solution - Pools

2 min read Intermediate Updated 2026-11-02
On/Off Humidity/Temperature/Brightness Open/close valve Sauna, Pool Temperature

Description

Pool equipment is controlled from the PIERRE system through the same outputs and inputs used elsewhere: relays for pumps and valves, dimmable or switched outputs for lighting, and temperature sensors for the water.

What Can Be Controlled

  • Water circulation — valves for massage jets, waterfalls and other circuits, each on its own output.
  • Water temperature — a temperature sensor in the circulation line provides the reading, and heating or cooling is switched from it.
  • Lighting — underwater lighting and the surrounding area, switched or dimmed, and usable in scenarios.
  • Covers and valves — motorised covers and actuated valves driven as outputs, manually or on a schedule.
  • Pumps and filtration — run on a schedule, or bound to a condition.

Automation

  • Filtration on a daily schedule, with the runtime set per season.
  • Heating held to a target water temperature, using the measured value from the pool sensor.
  • Lighting bound to sunset or to a scenario.

Technical Notes

  • Pumps and heaters are switched through contactors sized for their load; the controller relay drives the contactor coil, not the motor.
  • Pool areas have their own electrical zone requirements. Follow the local regulation for the installation zone, earthing and equipotential bonding — these are not decided by the control system.
  • Use a sensor rated for continuous contact with pool water and mount it in the circulation pipe, not in the basin.
  • Keep manual isolation available for every pump and heater, so the equipment can be serviced with the control system running.

Schemes

Pool - Wiring | 1. Contactor, 2. Circulation Pump, 3. Light, 4. Valve, 5. Heat Pump, 6. Temperature Sensor - Electric schemes

Pool - Wiring | 1. Contactor, 2. Circulation Pump, 3. Light, 4. Valve, 5. Heat Pump, 6. Temperature Sensor - Electric schemes

Cables

PositionWiresDiameterTypeComment
From Button to PIERRE30.5 mm²Cat5 UTP+12V, IN1, IN2...
From DS18B20 sensor to PIERRE30.75 mm²H07V-K+5V, GND, SIGNAL
From PIERRE to Mechanical relay20.75 mm²H07V-KOUT, GND
From PIERRE Controller to relay50.75 mm²H07V-KOUT1-4, GND
From relay to Contactor21.5 mm²NYM-OL, N
From relay to Circulation pump22.5 mm²NYM-OL, N
From relay to Lights21.5 mm²NYM-OL, N
From relay to Valve21.5 mm²NYM-OL, N
From Mechanical relay to Heat pump20.75 mm²H07V-KCOM, SIGNAL