Search
97 results for “contact” · 73 pages, 24 products
Magnetic contact sensor
The PIERRE Pro Magnetic Contact Sensor is an intelligent device engineered to enhance smart home security by monitoring the status …
1 Gang Dry Contact Light Module
The PIERRE Wave 1 Gang Dry Contact Light Module is a single-channel, dry contact relay designed for smart home integration. It provide…
Solution - Contact Sensor
A contact sensor reports whether an opening is open or closed — a door, window, gate, garage door or any othe…
matched in title, tags, body
Door/Window sensor
The PIERRE Wave Door/Window sensor is an intelligent device engineered to enhance smart home security by monitoring the status of doors and windows. U…
PIERRE T2 - Dry Contact Thermostat (110-230V AC, Black)
The PIERRE T2 - Dry Contact Thermostat is a flush-mounted room thermostat with two volt-free relay outputs, for zone control. P…
PIERRE T2 - Dry Contact Thermostat (110-230V AC, White)
The PIERRE T2 - Dry Contact Thermostat is a flush-mounted room thermostat with two volt-free relay outputs, for zone control. P…
PIERRE T2 - Dry Contact Thermostat (24V, Black)
The PIERRE T2 - Dry Contact Thermostat is a flush-mounted room thermostat with two volt-free relay outputs, for zone control. P…
PIERRE T2 - Dry Contact Thermostat (24V, White)
The PIERRE T2 - Dry Contact Thermostat is a flush-mounted room thermostat with two volt-free relay outputs, for zone control. P…
PREORDER - PIERRE Thor - Dry Contact Touch 4” Thermostat 230V
A 4" touch-screen thermostat with dry contact outputs for controlling boilers, zone valves, and heat pump enable inputs. Supports both Modbus RTU…
PREORDER - PIERRE Thor - Dry Contact Touch 4” Thermostat 24V
A 4" touch-screen thermostat with dry contact outputs for low-voltage HVAC control circuits. Powered by 24V and supporting both Modbus RTU and Zi…
PIERRE Partner - Contact Sensor
The Contact Sensor is used to detect the open or closed state of doors, windows, gates, and other movable eleme…
matched in title, body
Smart PIERRE - Magnet Contact Sensor
The Contact sensor section of the Smart PIERRE app shows whether a door or window is open or closed. Sensors ar…
matched in title, body
Contactor Schrack 20A three poles (3p)
The SCHRACK Contactor is designed for high-performance and reliable operation. It features a current capacity of 20A fo…
Magnetic sensor embedded for windows
…nsor embedded for windows is a flush-mounted reed contact that reports whether a window is open or closed. Normally-closed, 12 V DC, wired back to a PIERRE c…
Solution - Contactors
Contactor Control Description The PIERRE system can control contactors through a Solid State Relay (SSR) or…
matched in title, body
Solution - Elevator Control
…ation, the elevator control unit must provide dry-contact inputs for call and/or button commands. In most elevator systems, this type of interface is already…
matched in tags, body
Solution - Garage Door Control
… Controller controls a relay whose potential-free contact is connected to the garage door motor's external push-button or control input. The relay briefly cl…
matched in tags, body
Solution - Gas Boiler
… Controller controls a relay whose potential-free contact is connected to the boiler's external heat-demand input. By opening or closing this contact, PIERRE…
matched in tags, body
Solution - Gates Control
… Controller controls a relay whose potential-free contact is connected to the gate operator's dry-contact trigger input . The PIERRE system therefore sends t…
matched in tags, body
Solution - Push Button Control
… Controller Input When the button is pressed, the contact closes and sends the 12 V signal back to the corresponding Controller input. The lighting circuit o…
matched in tags, body
Contactor Schrack one pole 1~
Motion Sensor 360 (Flush Mount)
…gned for ceiling installations. It features a dry contact output and operates on a 9-24V DC power supply, making it ideal for smart home and security applica…
Presence Sensor 360 (Flush Mount)
…till or breathing. Ceiling flush mount, 360°, dry contact output, 12/24 V DC.
Solid State Relay with Socket (2A, 24–264V AC / 9-26V DC coil)
…d from a 9–26 V DC control signal, with no moving contacts. Rated 2 A and supplied with a DIN-rail socket.
Mechanical Relay
…rt of the RT series, features a single changeover contact (1CO) with a switching current capacity of 16A. It operates at a nominal voltage of 12VDC and has a…
Mechanical Relay 230V coil
…rt of the RT series, features a single changeover contact (1CO) with a switching current capacity of 16A. It operates at a nominal voltage of 12VDC and has a…
Mechanical Relay with Socket (16A 250V AC / 12V DC coil)
Coil Voltage 12 V DC Contact Rating 16 A @ 250 V AC (resistive) Contact Material Silver alloy (Ag alloy) Contact Resistance ≤100…
Presence Sensor 360 (Ceiling Mount)
… Humidity Non condensing 85 % RH Output Power Dry contact NO/NC Detection Angle 360° Detection Technology Radar-based motion/breathing Adjustable Features De…
Slim Mechanical Relay with Socket (6A 230V AC / 12 V DC coil)
Contact Rating 6 A @ 230 V AC Coil Voltage 12 V DC
PREORDER - PIERRE Thor - Fan Coil Touch 4” Thermostat (230 VAC, 0-10V Fan Speed, 0-10V Valve)
…oHS Compliant Yes Warranty 2 years Relay Type Dry Contact None Touch Screen Dimension 4 inch Touch Screen Resolution 480x480px pixels Power Supply 100-240V A…
PREORDER - PIERRE Thor - Fan Coil Touch 4” Thermostat (230 VAC, 3 Fan Speed, 1 Relay Valve or 0-10V)
…oHS Compliant Yes Warranty 2 years Relay Type Dry Contact None Touch Screen Dimension 4 inch Touch Screen Resolution 480x480px pixels Power Supply 100-240V A…
Fundamentals - PIERRE Building Structures and System Setups
…plays such as Berlin) Access Scenarios Guests can contact reception for assistance Reception can remotely open doors RFID / bell panels in garages or seconda…
matched in body
Fundamentals - PIERRE Pro System (Wired Installation)
…ure, humidity, and other sensors, door and window contact sensors, water leak detection and related protective functions, and other compatible building servi…
matched in body
Fundamentals - Software/Firmware Update Procedure for PIERRE Devices
…ure which firmware version should be used, please contact PIERRE Technical Support before proceeding. Important Notes Ensure the device remains powered and c…
matched in body
Mechanical Relay with Socket (13A 230V AC / 230V AC coil)
…ched live from existing controls, or a thermostat contact carrying mains. The contact switches up to 13 A at 230 V AC, enough for a boiler, immersion heater …
One-Bedroom Apartment Wiring Examples
…ature sensor. The entrance door lock and the door contact. Any socket that needs to be switched. Wiring Principle Star wiring: each point has its own cable t…
matched in body
PIERRE Data storage and Security
… to share this explanation with your customers or contact us if further technical clarification is required.
matched in body
PIERRE Partner - Doors Control
…Hide Activity if required. Enable Use Sensor if a contact sensor is fitted, then add the sensor. Submit and save the configuration. To edit a door, open the …
matched in body
PIERRE Partner - Fan Coil
…nly within a time window, stopping while a window contact is open, or reacting to another sensor. In Auto the unit then runs only while the rule is true and …
matched in body
PIERRE Partner - Leakage Sensor
…as a flood sensor, smoke detector, gas sensor, or contact sensor . For sensors with a normally closed (NC) output, use Change inverted . This reverses the in…
matched in body
PIERRE Partner - Lights
…le. Any wall push button for the circuit is a dry contact wired to a controller input. The controller is online in the PIERRE Partner app and has a free outp…
matched in body
PIERRE Partner - Passive Heating and Cooling
…or heating valve, an electric heater, a heat pump contact, a cooling ceiling valve. Before You Start The device is wired through a relay to a free controller…
matched in body
PIERRE Partner - Profile
…issue to technical support. Support and privacy — contact details for support and the privacy policy. Log out . Technical Notes Read the app version from her…
matched in body
PIERRE Partner - Push Button
…sh Button input allows connection of external dry-contact push buttons to a PIERRE controller. Each configured button can trigger one or more actions based o…
matched in body
PIERRE Partner - Siren
… Sensor detects movement. Trigger an alarm when a Contact Sensor is activated. Activate a siren when a Safety Detector enters an alarm state. Generate an aud…
matched in body
PIERRE Thermostat T2
…rements. Description PIERRE Wave Thermostat - dry contact 230V AC - Electric schemes full Schemes - 230V AC without controller (T2 controls the valves) Cable…
matched in body
PIERRE Wave - Indoor Siren (12V adapter)
… event the system can detect can sound it: a door contact opening, a water leak, a smoke or gas alarm, or a scene triggered by hand. It produces at least 85 …
Smart PIERRE - Alarm
…ample: Motion or presence sensors Door and window contact sensors Smoke sensors Leakage sensors Other compatible sensors and I/Os Multiple conditions can be …
matched in body
Smart PIERRE - Alerts
… https://www.youtube.com/embed/_H1KR95IdQ0 Magnet Contact Sensor Notifications Setup Automating a Smoke Detector, Siren, and Alerts https://www.youtube.com/e…
matched in body
Smart PIERRE - Delay Function
…ilation is turned OFF. Select the window magnetic contact as the condition. Set the magnetic contact condition to When Open . The delay condition will be bas…
matched in body
Smart PIERRE - Doors Control
…of the door, appropriate feedback, such as a door contact sensor , is required. Without such feedback, the PIERRE system may know the issued control command …
matched in body
Smart PIERRE - Fan Coil
… a delay or an existing I/O, for example a window contact that stops the unit while the window is open or a presence sensor that runs it only while the room …
matched in body
Smart PIERRE - Keys
…t leads outside. The open/closed state requires a contact sensor on the door or gate. Without it, only the locked state is real — the rest is what was comman…
matched in body
Smart PIERRE - Lights
…r an existing I/O such as a motion sensor, a door contact, a brightness sensor or a wall button. Conditions are joined with Or and And, and Add new Logical B…
matched in body
Smart PIERRE - Motion Sensor
…he PIERRE Partner app does not match the sensor's contact type. See the Partner Motion Sensor lesson. Wave motion sensors run on a battery and sleep between …
matched in body
Smart PIERRE - Open Doors/Gates via Smartphone
…eadable before acting. Magnetic Sensor A magnetic contact sensor should be fitted so the system knows whether the door or gate is physically open or closed. …
matched in body
Smart PIERRE - Passive Heating and Cooling
…rson remains still for an extended period. Window Contact A Window Contact can be used to temporarily stop or modify heating or cooling demand when an open w…
matched in body
Smart PIERRE - Reservation
… Dive into reservation specifics, including guest contacts, cleaning history, and access tools like digital QR keys or RFID tokens for secure, hassle-free pr…
matched in body
Smart PIERRE - Safety Detectors
…th compatible 12 VDC detectors that provide a dry contact or relay contact output. Supported Devices Smoke detectors. Heat detectors. Gas detectors. LPG dete…
matched in body
Solution - Alarm System Wiring
…er RFID Reader Electromagnetic Lock Motion Sensor Contact Sensor Siren System Functionality The system can provide: Intrusion detection Door and window monit…
matched in body
Solution - CO and other Gas Sensors
… manufacturer. Technical Notes A compatible relay contact alarm signal can be connected to the PIERRE Controller input. If the detector is powered directly f…
matched in body
Solution - Dimmable Light Control
… 0–10 V Extender and the Dimmer Slave 0–10 V. Dry contact (potential-free) momentary push buttons for the wall positions. The button must be a simple normall…
matched in body
Solution - Door Bell Buttons
A doorbell button is a dry-contact input on a PIERRE controller. When the contact closes, the controller raises a doorbell event, whic…
matched in body
Solution - Gate, Garage Door, Parking Ramp Control
…trial access systems Wired Control A standard dry-contact push button is connected directly to a PIERRE Controller input. Sequence: The user presses the push…
matched in body
Solution - Heat Recovery Unit (Recuperator)
…n the unit, control may be implemented using: dry contact / relay inputs , separate inputs for fixed fan speed levels, a 0–10 V control signal, or an appropr…
matched in body
Solution - Heating and Cooling with 0-10V
…t speed. From automation: a schedule, or a window contact that stops the fan. The regulation runs inside the controller, so it keeps working when the interne…
matched in body
Solution - Hot Tub with Massage Jets
…ical Notes Pumps and heaters are switched through contactors sized for their load; the controller relay drives the contactor coil, not the motor. Wet areas h…
matched in body
Solution - HVAC with Blower Speed
…ighttime. Stopping the unit when a door or window contact detects that it is open. Automatically selecting the required fan speed based on heating or cooling…
matched in body
Solution - IP Camera Integration
…assigned to the connection. If CGNAT is detected, contact your Internet Service Provider and request a Public Static IP Address . This is the recommended sol…
matched in body
Solution - Leak Sensor
…nput. Most third-party leak sensors provide a dry contact that closes when water is detected — this is the type that connects directly. Keep the cable run aw…
matched in body
Solution - Modbus Integration
…d to 0–10 V and Relay Control Modbus 0–10 V Relay contact Direction Read and write Command only Command only Feedback in the app Real state of the unit: on /…
matched in body
Solution - ON/OFF HVAC - Passive Heating Cooling (heating pumps)
… If the equipment requires a potential-free / dry-contact thermostat input , an appropriate potential-free contact must be provided from the PIERRE system. E…
matched in body
Solution - ON/OFF Light control
…s own output. Operating the Lighting From the dry-contact push button positions wired to the controller inputs. From the Smart PIERRE app. From scenarios, wh…
matched in body
Solution - Open/Close Door Locks
…nge the pin in the PIERRE Partner app. Should the contact sensor report the open or the closed state? Mount the sensor so that it closes when the door or gat…
matched in body
Solution - OTA Sync Integration for Effortless Booking Management
…ally revoked at checkout time This offers a safe, contactless, and hassle-free arrival experience for every guest. End-to-End System Integration PIERRE ’s sm…
matched in body
Solution - PID Regulated HC
…8B20 sensor must be installed with proper thermal contact to the pipe and sufficiently insulated from the surrounding ambient temperature. The 0–10 V control…
matched in body
Solution - PIERRE Alexa Integration
…Alexa, is [device name] open/closed?” (requires a contact sensor) Smart Plugs “Alexa, turn [device name] on/off.” “Alexa, is [device name] on?” Scenes “Alexa…
matched in body
Solution - PIERRE Smart Intercom
… Call Settings . Enable Resident List Call . Open Contact List Management . Select Add To , then Add Contacts . Step 3: Add a New Contact Remark: Enter a des…
matched in body
Solution - Pools
…ical Notes Pumps and heaters are switched through contactors sized for their load; the controller relay drives the contactor coil, not the motor. Pool areas …
matched in body
Solution - Rain Sensor
… be integrated into the PIERRE system using a dry-contact output or relay-based signal. Any rain sensor that provides a compatible contact output can be conn…
matched in body
Solution - Sirens
… various devices and events, including motion and contact sensors, smoke, gas and CO detectors, water leakage sensors, access control events, automation rule…
matched in body
Solution - Smoke and Fire Sensors
…to the controller I/O terminals via its own relay contact, so the detection signal reaches the system reliably. The sensor is configured in the PIERRE Partne…
matched in body
Solutions - Fan Coil control
…ontrolled by PIERRE in two ways: • Potential-free contacts: one contact switches winter/summer mode, another starts and stops the heat pump. • Modbus RTU: co…
matched in body
Tesla Residence
…ight of the entire property. Equipped with flood, contact, and motion sensors, the system proactively detects and addresses potential hazards, enhancing the …
matched in body
User Profile Settings
…seful application-related information, including: Contact information Privacy policy Terms and conditions (if available) Application version number This info…
matched in body
Vida Casa
… Door Control Cameras PIERRE Motion Sensor PIERRE Contact Sensor
matched in body
PIERRE Application Versions
… may be required when: Reporting software issues. Contacting technical support. Verifying compatibility with system components. Confirming installation of th…
matched in body
Smart PIERRE - Light Automation
…the light should follow daylight. Door and window contacts, wall buttons, other I/Os – open or closed, pressed, held or double-pressed, active or not active.…
matched in body
Solution - Blinds Control
…en it is released. What is wrong? Check the relay contacts and the protection varistor across the relay coil; a damaged relay or varistor can hold or release…
matched in body
Solution - Curtains Control
… end stops and run capacitor, and check the relay contacts for burnt or welded contacts. The motor does nothing and makes no sound. What should I check? Meas…
matched in body
Solution - Electrical Load Control
…oller sends a 12V DC control signal to a relay or contactor, and that relay or contactor switches the power supply or the control circuit of the connected de…
matched in body
Solution - Electrical Outlet
…s • HVAC equipment High-power loads may require a contactor instead of a standard relay. Using an undersized relay may result in: • Overheating • Reduced lif…
matched in body
Solution - Fan/Motor
…otor above the relay rating is switched through a contactor: the relay drives the coil, the contactor carries the load. Control On and off from the app and f…
matched in body
Solution - Pergola Control
…ed output module, an appropriately rated relay or contactor must be used. For position-based control, the actual full travel time of the pergola must be meas…
matched in body
Solution - PIERRE Controllers
… controlled through an appropriately rated relay, contactor, or other suitable power switching device. GND Ground/reference potential ( 0 V / − ) connection …
matched in body
Solution - Sauna
…hing must be implemented through a properly rated contactor and a suitably protected electrical circuit. The maximum operating time of the sauna heater must …
matched in body
Solution - Water Heater
…he PIERRE system, it is essential to use a relay, contactor, or switching device that is correctly rated for the electrical characteristics of the heater. Fo…
matched in body